Halogen-Free, Mud Resistant Power Cable RFOU 0.6/1(1.2)kV, P1/P8 Double Braided

Prysmian Draka Cables

Prysmian Draka Offshore Cables – LV, MV & HV Power (RFOU BFOU to IEC / NEK 606)

Prysmian draka cABLES

RFOU 0.6/1(1.2)kV Cable

EPR/EPR/TCWB/EVA Offshore Cables

Operating Temperature : 90°C

Operating Voltage : 0.6/1(1.2)kV

Prysmian Draka RFOU Offshore Cable Applications

power Cable nek ts 606

Fixed installation for instrumentation, communication, control and alarm systems in both EX (hazardous area Zone 0, Zone 1 and Zone 2) and safe areas, general purposes.  For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009.

power Cable Core Identification
  • Single core – Black
  • Two cores Blue – Brown
  • Three cores – Brown – Black – Grey
  • Four cores – Blue – Brown – Black – Grey
  • Five cores – Blue – Brown – Black – Grey – Black
  • Seven cores and above – White with black numbers
  • Two cores + earth (3G) – Yellow/green – Blue – Brown
  • Three cores + earth (4G) – Yellow/green – Brown – Black – Grey
  • Four cores + earth (5G) – Yellow/green – Blue – Brown – Black – Grey
  • G / X in cable description – G = One of the cores are yellow/green – X = no yellow/green core
  • Core identification – to HD308S2 – and IEC 60445 Ed 5.0 2010-08
RFOU Power Cable Construction Code Letter RFOU Power Cable Description
Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Insulation R EP-rubber, IEC 60092-360 (EPR)
Lay up / Shielding Cores laid up in concentric layers
Inner covering F Flame retardant and halogen-free thermoset compound
Tape over inner covering PET tape + rubberized Polyamide tape
Cable armour/screen O Two layers of tinned copper wire braid (double braid)
Tape over cable armour/screen PET tape + rubberized Polyamide tape
Cable outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360)
Marking text E.g. “meter” “year” DRAKA 01 RFOU 0,6/1kV P1/P8 3 x 185/95 mm2 IEC 60332-3-22
Cable manufacturing unit DRAKA 01 = Draka Norsk Kabel (Prysmian Group)
Outer sheath colour Black
Cable Standards Applied
Cable Terminations Joints Cleats 6.6kV 11kV 33kV

Cable Joints, Terminations, Glands & Cleats – available for 6.6kV 11kV and 33kV medium voltage (MV) power cables.

  • IEC 60092-353 – Design IEC 60228 class 2 – Conductor
  • IEC 60092-360 – Insulation IEC 60092-360 – Sheath
  • IEC 60332-1-2 – Flame Retardant
  • IEC 60332-3-22 – Flame Retardant
  • IEC 60754-1,2 – Halogen Free
  • IEC 61034-1,2 – Low Smoke
Cable Joints Cable Cleats Cable Glands - Prysmian Cables

T&D distribute the complete range of Prysmian cable cleats, cable joints and cable glands for onshore and offshore LV-HV power, control and instrumentation cables.