Halogen-Free, Unarmoured Mud Resistant Instrumentation Cable RU(i) 150/250(300)V, S11

Prysmian Draka Cables

Prysmian Draka Offshore Cables – LV, MV & HV Instrumentation (RFOU BFOU to IEC / NEK 606)

Prysmian draka cABLES

RU(i) 150/250(300)V Cable

EPR/EVA Offshore Cables

Operating Temperature : 90°C

Operating Voltage : 150/250(300)V

Prysmian Draka RU Offshore Cable Applications

Instrumentation Cable nek ts 606

Fixed installation for instrumentation, communication, control and alarm systems in both EX (hazardous area Zone 2) and safe areas. The cable meets the mud resistant requirements in NEK TS 606:2009.

Instrumentation Cable Core Identification
  • Pair – Black – Light Blue
  • Triple – Black – Light Blue – Brown
  • Quad – Black – Light Blue – Brown – Grey
RU Instrumentation Cable Construction Code Letter RU Instrumentation Cable Description
Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Insulation R EP-rubber, IEC 60092-360 (EPR)
Pair / Triple / Quad twisting Color coded cores twisted together and wrapped with polyestertape. Pairs/Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drainwire. Pairs/triples are identified by numbered tape or by number sprinted directly on the insulated conductors.
Lay up / Shielding Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped with a PETP tape
Inner covering No inner covering (Additional tapes may be applied)
Cable armour/screen No armour
Cable outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360)
Marking text E.g. “meter” “year” DRAKA 01 RU(i) 250V S11 2 pair 0,75 mm2 IEC 60092-376 IEC 60332-3-22
Cable manufacturing unit DRAKA 01 = Draka Norsk Kabel (Prysmian Group)
Outer sheath colour Grey or blue
Cable Standards Applied
Cable Terminations Joints Cleats 6.6kV 11kV 33kV

Cable Joints, Terminations, Glands & Cleats – available for 6.6kV 11kV and 33kV medium voltage (MV) power cables.

  • IEC 60092-376 (2003-05) – Design IEC 60228 class 2 – Conductor
  • IEC 60092-360 – Insulation IEC 60092-360 – Sheath
  • IEC 60332-1-2 – Flame Retardant
  • IEC 60332-3-22 – Flame Retardant
  • IEC 60754-1,2 – Halogen Free
  • IEC 61034-1,2 – Low Smoke
Cable Joints Cable Cleats Cable Glands - Prysmian Cables

T&D distribute the complete range of Prysmian cable cleats, cable joints and cable glands for onshore and offshore LV-HV power, control and instrumentation cables.