American National Standard for Electric Connectors – Sealed Insulated Underground Connector Systems Rated 600 Volts

 ➡ DOWNLOAD

Cable Terminations

THORNE & DERRICK are national distributors LV, MV & HV Cable Installation, Cable Pulling, Cable Jointing, Substation & Electrical Equipment – we service UK and global businesses involved in cable installations, cable jointing, substation, overhead line and electrical construction at LV, 11kV, 33kV and EHV.

Since 1985, T&D have established an international reputation based on SERVICE | INTEGRITY | TRUST.

Contact us for 3M Electrical, ABB, Alroc, AN Wallis, CATU Electrical, Cembre, Centriforce, CMP, CSD, Elastimold, Ellis Patents, Emtelle, Euromold, Filoform , Furse, Lucy Electric & Zodion, Nexans, Pfisterer, Polypipe, Prysmian, Roxtec, Sicame, WT Henley.

Joints Terminations Glands Cleats Connectors 11kV 33kV

Invitation

Thorne & Derrick invite you to join LinkedIn’s largest LV-HV Electrical Discussion Group : Low & High Voltage Power, Cabling, Jointing & Electricals. 

Discussion subjects include cable installations, cable jointing, substation, overhead line and electrical construction at LV, 11kV, 33kV and EHV. Network, engage and promote your profile, company or products with over 10,000 influencers.

LinkedIn - Joints Terminations Glands Cleats 11kV 33kV HV

LinkedIn - 3M Nexans Euromold Elastimold Pfisterer Prysmian

Feeder Pillars

 

  • uploaded by Chris Dodds - Thorne & Derrick Sales & Marketing Manager
    
    

Feeder Pillars

Thorne & Derrick International are leading UK Distributors of the Lucy Zodion range of Fortress brand feeder pillars designed to provide LV Power Distribution across a diverse range of market sectors including:

  • Street Lighting
  • EV Charging
  • Rail
  • Urban Regeneration
  • Highways & Motorways
  • Airports
  • Retail & Leisure
  • Utilities – Water, Gas & Electricity

Feeder pillars are manufactured to the highest level of standard including Cast Iron, Stainless Steel, Glass Resin Plastic (GRP) and Hot Dip Galvanised Steel (HDG).

Here follows the list of optional extras available for use with Fortress Feeder Pillars:

Pillar Code Pillar Options Pillar Type
A Green Colour Heritage
B Infill Panel For Root Section Heritage
C Bar Lock Heritage
D Yale Lock Slim | Double | Slimline | Heritage
E Hasp & Staple Single | Double | Slimline
F Alternative Paint Colour Heritage
G Heater Kit Slim | Double | Slimline | Heritage
H 13 Amp Socket Kit Slim | Double | Slimline | Heritage
I Lighting Kit Slim | Double | Slimline | Heritage
J Document Pocket Inside Feeder Pillar Door Slim | Double | Slimline
SS Stainless Steel Fortress
S Special Requirement Slim | Double | Slimline | Heritage
SL Special Locks – State Lock Type Required Fortress | Heritage

 

More Reading  ➡ 

Lucy Zodion

THORNE & DERRICK SPECIALIST ELECTRICAL DISTRIBUTORThorne & Derrick

LV ♦ MV ♦ HV

T&D distribute the most extensive range of LV, MV & HV Cable Jointing, Terminating, Pulling & Installation Equipment – we service UK and international clients working on underground cables, overhead lines, substations and electrical construction at LV, 11kV, 33kV and EHV transmission and distribution voltages.

Cable Joints Glands Cleats Lugs - LV Low Voltage

LV – Low Voltage Cable Joints, Glands, Cleats, Lugs & Accessories (1000 Volts)

Cable Joints Terminations - MV HV Medium High Voltage

MV HV – Medium & High Voltage Cable Joints, Terminations & Connectors (11kV 33kV EHV)

Cable Protection Duct Seals Rollers

Cable Laying – Underground Cable Covers, Ducting, Seals & Cable Pulling Equipment

CATU Electrical Safety Equipment

T&D, CATU Electrical Safety & Arc Flash Protection Specialists for SAP’s, Linesmen, Jointers & Electrical Engineers – Largest UK Stockist

 

Landlords Feeder Pillars - An Example Specification

Feeder Pillars

  • uploaded by Chris Dodds - Thorne & Derrick Sales & Marketing Manager
    

Thorne & Derrick are the leading designer, distributor and supplier in the UK of feeder pillars manufactured by Lucy Zodion – a complete range of standard, customised and pre-wired types from the Lucy Fortress range of feeder pillars are available to suit all LV Electrical Power Distribution requirements.

This includes power distribution pillars to provide LV electricity supply to new housing developments, multi-occupancy buildings and permanent supply kiosks for properties.

Here follows an example of a Landlords Feeder Pillar specification highlighting the flexibility and capability of Thorne & Derrick to liase with consultant engineers and specifiers to meet the needs and electrical power requirements of the residential, housing and accommodation market sectors.

Landlord’s Services

FEEDER PILLARs

Mechanical & Electrical Engineering Services – Manor House Development (Travelodge Addendum Specification)

A 60kVA 100A 3 phase electricity supply shall be provided.

This supply shall be terminated in a 100Amp 3 phase service cut-out mounted on a class 0 timber backing board within a Landlords feeder pillar.

The feeder pillar / control cabinet shall be vandal resistant IP65 hot dipped galvanised steel cabinet as per the Lucy Fortress Pillars or equal and approved.

The feeder pillar shall be painted to match the lighting columns and fitted with a Yale Lock or equal and approved.

Provide a new 100A 3 phase metal cased distribution board enclosed within a feeder pillar to serve the landlords services i.e. external lighting, vehicle charging points, CCTV, petrol interceptor.

All distribution boards shall be provided with integral main switch disconnectors miniature circuit breakers, blanks, lockable doors and 3 sets of keys to each of the door locks.

Provide PVC/PVC insulated single core cables from the service cut-out to the revenue meter and from the revenue meter to the distribution board.

Distribution boards shall generally employ type C miniature circuit breakers for final sub circuit protection.

The distribution board shall be provided with Class II surge protection as detailed in BS EN 62305.

The distribution board shall be sized to include a minimum of 25% spare outgoing ways arrnaged evenly over each phase, which shall be fitted with individual blanking plates.

Distribution boards shall employ miniature circuit breakers for final sub circuit protection. Circuit breakersshall be selected to take account of the thermal and magnetic effects of loads serrved, taking due account of any starting currents. Particular care shall be taken when selecting circuit breakers protecting circuits supplying LED driver units.

Distribution boards shall be labelled and scheduled in accordance with BS7671 – miniature circuit breakers shall comply with relevant British and European standards.

Feeder Pillars

 

Feeder Pillars

Galvanised & Stainless Steel | Cast Iron | GRP | Pre-Wired | Electrical Power LV

 

Feeder Pillars

Largest UK Feeder Pillar Stocks – fast delivery from stock or on short lead-times

 

âž¡ Further Reading

 

THORNE & DERRICK SPECIALIST ELECTRICAL DISTRIBUTORThorne & Derrick

LV ♦ MV ♦ HV

T&D distribute the most extensive range of LV, MV & HV Cable Jointing, Terminating, Pulling & Installation Equipment – we service UK and international clients working on underground cables, overhead lines, substations and electrical construction at LV, 11kV, 33kV and EHV transmission and distribution voltages.

Cable Joints Glands Cleats Lugs - LV Low Voltage

LV – Low Voltage Cable Joints, Glands, Cleats, Lugs & Accessories (1000 Volts)

Cable Joints Terminations - MV HV Medium High Voltage

MV HV – Medium & High Voltage Cable Joints, Terminations & Connectors (11kV 33kV EHV)

Cable Protection Duct Seals Rollers

Cable Laying – Underground Cable Covers, Ducting, Seals & Cable Pulling Equipment

CATU Electrical Safety Equipment

T&D, CATU Electrical Safety & Arc Flash Protection Specialists for SAP’s, Linesmen, Jointers & Electrical Engineers – Largest UK Stockist

 

PILC Cable Joints

PILC Cable Joints & Connectors | Sicame

  • uploaded by Chris Dodds - Thorne & Derrick Sales & Marketing Manager

Heat Shrink

PILC Cables Paper Insulated Lead Cables

Oil barrier heat shrink sleeves are applied to PILC cables to prevent the cable oil from dripping out and can be used to increase the cable insulation up to 33kV for joints and terminations. These oil barrier heat shrink tubes are made from high quality cross linked polyolefin material and are clear (transparent) – the heat shrink tubes can be supplied on continuous spools or pre-cut lengths.

Prior to jointing cables the paper insulated cables can be wiped down using cable cleaners to remove the oil residue and ensure clean jointing of cables.

Thorne & Derrick supply LV cable jointers with an extensive range of cable jointing kits (heat shrink, Cold Shrink, resin cast), cable jointing tools, underground cable protection and cable pulling equipment to enable the safe and reliable installation of low voltage cables 600/1000 volts.

Thorne & Derrick can recommend LV Jointer Training Courses for Jointers requiring Competency Certification to joint PILC cables covering :

• Identification Of LV Cable Types
• Single Phase Sub Service Transition Straight & Breech Joint
• Three Phase Sub Service Transition Straight & Breech Joint
• Single & Three Phase PILC Cutout
• Single & Three Phase PILC Pot End
• Three Phase & Single Phase PILC Service Joint
• Transition Breech & Straight Joint

Heat Shrink Tubes

THORNE & DERRICK SPECIALIST ELECTRICAL DISTRIBUTORThorne & Derrick

LV ♦ MV ♦ HV

T&D distribute the most extensive range of LV, MV & HV Cable Jointing, Terminating, Pulling & Installation Equipment – we service UK and international clients working on underground cables, overhead lines, substations and electrical construction at LV, 11kV, 33kV and EHV transmission and distribution voltages.

  • Distributors for: 3M, ABB, Alroc, Band-It, Catu, Cembre, Centriforce, CMP, Elastimold, Ellis Patents, Emtelle, Furse, Lucy Zodion, Nexans Euromold, Pfisterer, Polypipe, Prysmian, Roxtec.
Cable Joints Glands Cleats Lugs - LV Low Voltage

LV – Low Voltage Cable Joints, Glands, Cleats, Lugs & Accessories (1000 Volts)

Cable Joints Terminations - MV HV Medium High Voltage

MV HV – Medium & High Voltage Cable Joints, Terminations & Connectors (11kV 33kV EHV)

Cable Protection Duct Seals Rollers

Cable Laying – Underground Cable Covers, Ducting, Seals & Cable Pulling Equipment

CATU Electrical Safety Equipment

T&D, CATU Electrical Safety & Arc Flash Protection Specialists for SAP’s, Linesmen, Jointers & Electrical Engineers – Largest UK Stockist

INVITATION

Thorne & Derrick invite you to join LinkedIn’s largest LV-HV Electrical Discussion Group : Low & High Voltage Power, Cabling, Jointing & Electricals. Discussion subjects include cable installations, cable jointing, substation, overhead line and electrical construction at LV, 11kV, 33kV and EHV. Network, engage and promote your profile, company or products with over 10,000 influencers.

Thorne & Derrick LinkedIn Discussion Group

Thorne & Derrick LinkedIn Discussion Group - Join

Arc Flash and Isolation Safety Conference Manchester 2019

Article by Chris Dodds – Thorne & Derrick Sales & Marketing Manager

Arc Flash & Isolation Safety Conference – Manchester 2019

The 3rd Arc Flash & Isolation Safety Conference took place in Manchester on 21–22 May 2019.

The two-day event brought together electrical safety professionals to discuss arc flash hazards, safe isolation and practical risk management.

Its programme focused on real workplace experiences, technical developments and the challenges faced by electrical engineers.

Delegates had the opportunity to hear from specialists, review case studies and discuss ways to improve electrical safety.

The event also examined relevant standards, risk assessment methods and the selection of appropriate arc flash protective equipment.

Why Is Arc Flash Safety Important?

An arc flash is a dangerous electrical event that can release intense heat, light and pressure.

It may occur when an electrical fault produces an arc through the surrounding air.

Workers exposed to an arc flash can suffer severe burns and other injuries.

Effective risk management therefore requires suitable electrical system design, safe working procedures and appropriate protective measures.

Where a residual thermal hazard remains, correctly selected arc-rated PPE can provide an additional layer of protection.


Arc Flash Conference – Technical Topics

The conference addressed several important areas of electrical safety.

Its programme included the following technical subjects:

  • The human factor in electrical safety: Reducing errors and improving workplace performance.
  • Arc flash risk assessments: Understanding the UK approach to electrical hazard evaluation.
  • Arc-rated clothing programmes: Developing and implementing suitable protective clothing arrangements.
  • Maritime electrical safety: Managing arc flash hazards through vessel electrical system design.
  • IEC 62271-200: Internal arc classification of relevant high voltage switchgear.
  • IEC 61439: Improving safety in low voltage switchgear assemblies.
  • Electrical safety training: Identifying gaps in worker knowledge and competence.
  • Arc flash PPE: Understanding when protective clothing is required.
  • Nuclear industry risk assessment: Lessons from a Swedish nuclear power plant.
  • Protective clothing design: Understanding the construction and performance of arc flash PPE.
  • IEEE 1584: Methods used to calculate arc flash incident energy.
  • Practical workplace case studies: Applying arc flash assessments to real electrical installations.
  • PPE selection methods: Comparing approaches to electrical arc hazard assessment.

Together, these sessions explored both the technical and human aspects of electrical safety.


Legal Responsibility and Electrical Safety Management

One of the conference sessions focused on the legal responsibilities associated with electrical installations.

Anthony Smith, CEO of Lantei Compliance Services and The Electrical Safety Network, delivered the presentation.

The Electricity at Work Regulations 1989

Anthony’s session examined the legal requirements for maintaining electrical systems and equipment.

It covered low, medium and high voltage installations, with particular attention to the responsibilities of duty holders.

The presentation included discussion of:

The aim was to help duty holders understand their responsibilities and manage electrical safety more effectively.

This presentation appeared as Session 14 in the original conference programme.

Electrical Safety Equipment

Safe electrical working may require specialist testing and protective equipment.

For example, appropriate voltage detectors and portable earthing arrangements can form part of approved isolation procedures.

Thorne & Derrick supply electrical safety equipment for suitable LV, MV and HV applications.


Arc Flash Conference – Day 1 Highlights

The first day explored electrical safety culture, risk assessments, protective equipment and switchgear design.

Speakers also shared case studies from different industries.

Day 1 Speakers and Presentations

Speaker Presentation
Jim Pollard The Human Factor in Electrical Safety – Ways to Reduce Error and Improve Performance
John Maplesden Arc Flash Risk Assessment from a UK Perspective – What’s New?
Derek Sang Building and Implementing a Flame-Resistant/Arc-Rated Clothing Programme
Shaun White Arc Flash in the Maritime Industry – Hazard Mitigation Through System Design on a New-Build Vessel
Andy Seccombe Internal Arc Classification According to IEC 62271-200
Lutz Graufmann Improving the Safety of LV Switchgear Assemblies According to IEC 61439
Kevin Hann Electrical Training Gaps and Their Arc Flash Safety Implications
Anthony Long Arc Flash PPE – Do You or Don’t You Need It?
Thomas Winter Arc Flash Risk Assessment – Case Study from Sweden’s Largest Nuclear Power Plant

International Keynote Speaker – Jim Pollard

Jim Pollard, an arc flash specialist associated with Unlimited PPE Inc., was featured as an international keynote speaker.

His presentation focused on the human factors that influence electrical safety.

For example, working practices, decision-making and training can all affect how workers respond to electrical hazards.

Addressing these factors can help organisations improve safety performance.


Arc Flash Conference – Day 2 Highlights

The second day focused on arc flash PPE, calculation methods and practical risk assessment.

It also included a session on electrical safety responsibilities.

Day 2 Speakers and Presentations

Speaker Presentation
Jim Pollard The Anatomy of Arc Flash PPE
Alan O’Kelly IEEE 1584 – Guide for Performing Arc Flash Hazard Calculations
Pay Mynett Three Case Studies Exploring Practical Arc Flash Risk Assessment in the Workplace
Thomas Jordan PPE Selection – Practical Experience and Comparison of Arc Assessment Methods
Anthony Smith Duty Holder Responsibility and Electrical Safety Management

IEEE 1584 and Arc Flash Calculations

The conference included a presentation about IEEE 1584 and arc flash hazard calculations.

Arc flash calculations help engineers estimate the incident energy associated with certain electrical faults.

These results can support risk assessment and protective measures within the method’s defined scope.

However, calculations require accurate electrical system information and the appropriate calculation standard.


Download the 2019 Arc Flash Conference Brochure

The original conference brochure contains details of the event programme, speakers and registration arrangements.

Although the event has concluded, the document remains a useful historical reference.


What Could Delegates Learn?

The conference aimed to help electrical professionals develop their understanding of arc flash safety.

Its original programme highlighted several learning objectives.

  • Understand developments in UK, European and international electrical safety standards.
  • Review case studies involving arc flash hazard mitigation.
  • Explore methods of assessing electrical arc flash risks.
  • Understand the potential injuries associated with an arc flash.
  • Learn about electrical safety responsibilities and workplace compliance.
  • Compare approaches to arc flash assessment.
  • Understand the selection, testing and maintenance of arc flash PPE.
  • Explore electrical safety training requirements.
  • Share experience with electrical safety specialists and other delegates.

The original programme also referenced NFPA 70E, CSA Z462, BS 7671 and IEEE 1584.

These references reflect the standards discussed during the 2019 event. Current projects must use the applicable editions and requirements.


Who Was the Conference Designed For?

The event targeted professionals involved in electrical engineering, workplace safety and industrial risk management.

Its intended audience included:

  • Electrical technicians, engineers and managers.
  • Engineering and maintenance managers.
  • Electrical risk assessors.
  • Electrical design engineers.
  • Manufacturers of PPE and safety equipment.
  • Safety advisers and facilitators.
  • Instrumentation and control engineers.
  • Process safety and loss prevention managers.
  • Government safety regulators and inspectors.
  • Occupational health and safety managers.
  • Electrical training managers.
  • Tradespeople working in potentially explosive environments.

Thorne and Derrick International company logo


2019 Arc Flash Conference – Event Details

The following details are retained from the original event announcement for historical reference.

Conference 3rd Arc Flash & Isolation Safety Conference
Start Date 21 May 2019
End Date 22 May 2019
Venue Marriott Manchester – Victoria & Albert Hotel
Original Registration Start 1 February 2019
Original Listed Cut-Off Date 31 May 2019
Standard Delegate Price £750
Early Booking Price £675 until 23 April 2019
Listed Group Price £1,500

Historical event: The conference has finished, and the registration prices and discounts are no longer active.

Original Delegate Discounts

The original event announcement included an early booking discount of 10%, equivalent to £75 per delegate.

It also advertised a three-for-two delegate offer.

These promotions applied only to the 2019 conference.


Arc Flash Statistics and Electrical Safety Awareness

The original conference article featured historical arc flash statistics from ISHN.

These figures included:

  • 30,000 reported arc flash incidents per year.
  • 7,000 burn injuries per year.
  • 2,000 hospitalisations per year.
  • 400 fatalities per year.

However, the original article did not establish a consistent reporting geography, timeframe or independently verified dataset for these figures.

Therefore, they should be regarded as historical claims rather than current annual statistics.

For electrical safety planning, organisations should use reliable incident information alongside site-specific risk assessments and applicable guidance.

Historical arc flash incident statistics from the original conference article

Historical Arc Flash Statistics – Source: ISHN


Thorne & Derrick – Arc Flash and Electrical Safety Equipment

Thorne & Derrick International supply specialist equipment for electrical installation, maintenance and power distribution.

Our product range includes arc flash protection and electrical safety equipment for LV, MV and HV applications.

We support utilities, electrical contractors and industrial businesses working on power infrastructure projects.

Electrical Safety Product Categories

Explore our specialist product ranges:

Electrical Equipment Manufacturers

Our original article featured electrical equipment manufacturers including 3M, CMP, Ellis Patents, Nexans Euromold, Elastimold, PFISTERER, Prysmian, Alroc, CSD, Roxtec, CATU, Cembre, Lucy Zodion, ABB and Emtelle.

These manufacturers supply different products for cable installation, electrical distribution and related applications.

11kV and 33kV cable accessories from established electrical manufacturers

Power Cable Jointing and Installation

Thorne & Derrick also provide technical product information for electrical cable installation work.

Our Cable Jointers Photo Blog features contributions from electrical professionals working on LV, MV and HV installations.

For further information about our product offering, explore the Thorne & Derrick Power Brochure.

Cable joints terminations and connectors from Nexans Euromold PFISTERER and 3M

Thorne and Derrick cable jointing terminating and connecting solutions

Thorne & Derrick – Joint | Terminate | Connect

Thorne and Derrick International electrical equipment distributor

Blog

Voltage Detectors Explained: Types, Uses & Safe Voltage Testing

Published 16 Nov 2026

Voltage Detectors Explained: Types, Uses & Safe Voltage Testing

Voltage detectors are electrical safety instruments used to identify the presence or absence of voltage on electrical equipment and conductors. They are used by electricians, electrical engineers, utilities and maintenance teams working on low voltage (LV), medium voltage (MV)...

Read More

Associated manufacturers
Share this page
Share this page
X

Get a quote

Complete the form below to make an enquiry about products.

  • This field is for validation purposes and should be left unchanged.
  • Please enter your full name.
  • Please enter your contact telephone number.
  • Please enter your e-mail address.
  • Please select if you are enquiring about products for the UK or for export.