UK DNO: SSE Scottish & Southern Energy
Approved Manufacturer: Nexans Cables
Voltage: Medium Voltage Cables
Cable Type: 11kV Power Distribution
Solid Aluminium Conductors: 150sqmm, 500sqmm,630sqmm, 800sqmm, 1000sqmm
➡ Download SSE 11kV XLPE CWS Single Core Al BS7870:2011 4.10 150-1000sqmm

Stock | Supply | Service | Cables | Joints | Terminations | Connectors 33kV
JOINTÂ ♦ TERMINATEÂ ♦ CONNECTÂ ♦ GLANDÂ ♦ CLEATÂ ♦ CRIMPÂ ♦ DUCTÂ ♦ SEALÂ ♦ REPAIRÂ ♦ CABLE ♦ TOOLS

➡ The following cable record library provides a summary of installed offshore wind farm power cables at the following projects to enable the selection of suitable 33kV Tee Connectors or joints and terminations to carry out repairs or maintenance on strings typically to standard and specification IEC 60502-2.
The Euromold brand of separable connectors manufactured by Nexans are used to terminate MV Medium Voltage 33kV power cables in converter based applications in the onshore and offshore wind farm industry.
Euromold brand 33kV Separable Connectors are trusted by Windfarm Developers, Owners & Operators to provide reliable and safe service life performance – each MV cable connector is tested for AC withstand and PD (Partial Discharge) prior to shipment and meets the requirement of CENELEC HD 629.1.
To support the installation of Nexans Euromold products, Thorne & Derrick can organise and accept bookings for 33kV Cable Jointer Training.
Offshore Wind Farms & Cables
Cable Manufacturer Nexans
Project:Â Horns Rev 02 (HRV02). Country: Denmark. Location: Offshore.
Project:Â West of Dutton Sands (WDS). Country: UK. Location: Offshore.
Project:Â Anholt (ANH). Country: Denmark. Location: Offshore
Project: Lincs Wind Farm. Country: UK. Location: Offshore
Project: Westermost Rough. Country: UK. Location: Offshore
Cable Manufacturer TF Kable
Project:Â Race Bank (ROW) + Race Bank (ROW2). Country: UK. Location: Offshore.
Cable Manufacturer ABB
Project:Â Burbo Bank (BBW01). Country: UK. Location: Offshore.
Cable Manufacturer Draka
Project: Walney (WOW01-02). Country: UK. Location: Offshore.
Includes:
- 33kV XLPE 3 X 150sqmm Copper IEC60228 Class 2 19/33kV (36kV) + 2 X 24 SM OFÂ
- 33kV XLPE 3 X 500sqmm Copper IEC60228 Class 2 19/33kV (36kV) + 3 X 24 SM OF
Includes:
- 33kV XLPE 3 X 150sqmm Copper IEC60228 Class 2 19/33kV (36kV) + 2 X 24 SM OFÂ
- 33kV XLPE 3 X 500sqmm Copper IEC60228 Class 2 19/33kV (36kV) + 3 X 24 SM OF

T&D are Specialist Distributors to the UK and international Offshore Wind industry to provide safe and reliable LV HV Electrical Cable & Power Distribution Systems – we are highly customer responsive and absolutely committed to providing a world-class service.
We provide expert technical support and supply from a multi-million pound stock holding:
Cable Joints, Terminations & Connectors
Earthing & Lightning Protection
Cable Accessories – Cable Lugs & Cable Glands
Circuit Protection & Fuses
Cable Cleats & Clamps
Electrical Safety Equipment
Cable Pulling & Laying Equipment
Arc Flash Protection & Clothing
Cable Duct Seals & Cable Transit Systems
Surge Arresters & Bushings 33kV MV HV
We have an International Distribution Agreement with Nexans Power Accessories UK to supply their Heat Shrink and Cold Applied ranges of 11kV/33kV/66kV joints and terminations and Euromold brand of separable connectors.
Since 1985, we have established an international reputation based on Service, Integrity and Trust – contact us.

FiloSeal+HD FIRE has now been tested by London Underground for the safe and effective sealing of cables and ducts on the underground rail network – the duct seal system has been rigorously and successfully tested against smoke and toxicity emissions according to LUL S1085 Standard.Â
London Underground LUL – S1085
Fire Safety Performance of Materials
Rail Stations & Tunnel Infrastructure
LUL S1085 standard specifies the requirements for materials within all locations as listed in LU Standard S1086 with regard to:
a) Combustibility
b) Smoke Emission
c) Toxic Fume Emission
Note: This standard does not cover the wider aspects of fire engineering and it may be necessary to invoke other London Underground, National or European Standards to cover fully all aspects of fire safety for a particular application. Guidance is available in G085.
Purpose
The purpose of this standard is to define the requirements for the fire safety performance of materials, installed on the London Underground (LU) Stations and Tunnel Infrastructure.
The business objective of this standard is to ensure that the risk to which the public and employees are exposed is controlled to a level that is as low as reasonably practicable.
FiloSeal+HD FIRE is also approved to the following rail industry standards:
- Railway Applications – Fire Protection On Railway Vehicles BS EN45545
- French Standard – Fire Test to Railway Components CIt NF F16-101
All these tests look at the following: toxicity values when the product is burning, smoke index value and the amount of oxygen required for combustion.

Thorne & Derrick – Stickists & Suppliers of MV HV Joints, Terminations & Connectors
Specialist Suppliers To The UK & International Rail Industry
Thorne & Derrick International, based in the UK, are leading Specialist Distributors & Stockists of LV, MV & HV Cable Installation, Jointing, Substation & Electrical Equipment to the Rail industry.
➡ Product Categories: Duct Seals | Cable Cleats | Cable Glands | Electrical Safety | Arc Flash Protection | Cable Jointing Tools | Cable Pulling | Earthing | Feeder Pillars | Cable Joints LV | Joints & Terminations MV HVÂ
Joints ♦ Terminations ♦ Glands ♦ Cleats ♦ Earthing ♦ Ducts ♦ Seals ♦ Safety ♦ Tools ♦ Fusegear

11kV Cable
SSE 11kV Cable Single Core 150sqmm Al XLPE BS7870:2011 Section 4.10.
Scottish & Southern Energy Power Distribution
Description:Â 11kV XLPE tree retardant insulation, stranded (with water blocking) or solid aluminium phase conductors with 35sqmm copper wire screen.
Requirements 11kV
- BS7870: 2011 Section 4.10
- Longitudinal Water Blocking Under Screen Wires
- Insulation Screen Must Be Cold Strippable
- Equalising Wire Or Tape On Screen Wires
SSE Stock Code: 015079
11kV 33kV
Contact us for 11kV & 33kV Cables including complete range of cable accessories and installation equipment including cable cleats, cable covers (Tapetile 11kV | Stokbord 33kV), cable pulling/laying equipment and cable jointers tools for the preparation of medium/high voltage power cables, 11kV/33kV.
Refer to Further Reading download â–¼

A Guide To High Voltage Earthing Conductors
What size earthing conductors should I use?
And, is there a simple table I can use for this high voltage earthing design?
These are great questions that I’m often asked. This post answers these questions together with the choice of conductor materials and jointing method within a high voltage earthing design project.
Assessing conductor size is entirely dependent on the electrical configuration and the load that the conductor must take. For example, an above-ground bonding conductor serves to transfer current with minimal voltage drop, from A to B.
A directly buried conductor has an additional purpose, that of leaking the fault current/voltage into the local geology (as part of an electrode).
When considering Lightning, the same conductor above might also see a high-frequency component and which will impose yet another requirement.
High Voltage Earthing Conductors
Design Considerations
In IEEE-std80Æ’Â Guide for Safety in AC Substation Grounding, section 11 – states the basic requirements are:
Each element of the grounding system, including grid conductors, connections, connecting leads, and all primary electrodes, should be so designed that for the expected design life of the installation, the element will
a) Have sufficient conductivity, so that it will not contribute substantially to local voltage differences.
b) Resist fusing and mechanical deterioration under the most adverse combination of a fault magnitude and duration.
c) Be mechanically reliable and rugged to a high degree.
d) Be able to maintain its function even when exposed to corrosion or physical abuse.
Earthing Materials
Copper has traditionally been the go-to material for years in high voltage earthing because it is not only highly conductive but also resistant to most sources of in-ground corrosion.
Similarly, aluminium has sufficient conductivity but suffers from in-ground corrosion, and the oxidation that forms around its surface is not conductive, therefore, compromises the conductor’s ability to leak current when buried, which is why buried aluminium conductors is a no-no.
Stainless steel or mild steel (when appropriately coated – galvanised or copper bonded), on the other hand, may not have the conductivity of copper or aluminium but it is sufficiently conductive to be utilised as a buried conductor.
Dealing with the Heat
So now we’ve covered the materials that are widely used for high voltage earthing.
Point ‘b’ from IEEE-std 80 above calls for the conductor to retain its mechanical strength when being exposed to a fault.
Conductors get hot when current flows through them. And they will potentially be at their hottest when subjected to a fault from the electrical system. This fault means the conductor needs to maintain its physical integrity as temperature increases and not transform into a shower of hot molten metal!
Up to this point, we’ve discussed conductor conductivities, materials and thermal-mechanical characteristics.
Another consideration for high voltage earthing is the method of the joint between conductors.
Conductor Joints
Joints in conductors are as critical to current-flow as the conductors themselves. The jointing method must not allow the joint to introduce excessive resistance. Therefore, the selection of the jointing method will impact the earthing system’s thermal resilience massively. This thermal resilience is why welded joints are the go-to choice for the high voltage earthing system.
Welded joints achieve the nearest physical match to the native conductor itself and are the gold-standard in conductor jointing because they accomplish a molecular similarity to the native material’s conductivity, as well as similar mechanical robustness.
Here’s an example of a safe method of igniting an exothermic weld.
A Word of Caution
Bolted joints and clamps are made up of multiple parts which can creep and loosen over time. Loosening will add resistance across conductor joints, which as previously mentioned… is not a good thing (thermal runaway is a topic for another day).
Bolted joints fall into the category of mechanical joint methods and have a derating factor to keep the conductors operating at lower temperatures. When designing a high voltage earthing system, this means the seemingly unrelated selection of jointing method will also impact the conductor size calculation.
IEEE adiabatic equation

Calculating High Voltage Earthing Conductors
In Summary
So there you have it. Without going into great detail, the following factors influence conductor sizing:
- The magnitude and duration of fault current (i.e. the heat source)
- The method used for the joint
- The conductor material
- The conductor’s role in the high voltage earthing design
These factors may vary project by project, so, using a particular size of the conductor on a previous project does not mean that the same will apply to the next project, which means calculating conductor sizes (adiabatic equation) to fit the particular requirements of the project is usually very necessary.
Æ’ IEEEÂ P80 – Guide for Safety in AC Substation GroundingÂ
This guide is primarily concerned with outdoor ac substations, either air-insulated or gas-insulated. With proper caution, the methods described herein are applicable to indoor portions of such substations, or to substations that are wholly indoors. No attempt is made to cover the grounding problems peculiar to dc substations. A quantitative analysis of the effects of lightning surges is also beyond the scope of this guide.
Further Reading
Ian Griffiths CEng, MBA, BEng, MIET
Principal Engineer at GreyMatters, an Earthing & Lightning Protection Consultant of 27 years, one of the top 1% UKAS accredited CDEGS consultants and professional advisor to international utility companies, data centre and infrastructure developers. Risk Assessment Surveys and measurements for substation earthing or generation schemes on your electrical earthing system, voltages from 1kV to 765kV are undertaken by their highly qualified engineers.
Some LinkedIn Comments
Charles Shannon Senior Application Engineer at IMCORP
Hey Chris Dodds and Ian Griffiths – Substation Earthing. Great subject. I would add two minor clarifications to that blog. #1 when mentioning buried earthing conductors it’s worth clarifying that is for unjacketed cables. Additionally there in the maximum energy calculation note that with proper surge arresters this energy can be significantly reduced which can significantly reduce the size and thus the cost of the cable.
Ian Griffiths – Substation Earthing
Hi Charles, you might be right to add an additional clarification re buried conductors. Still, the piece is intentionally brief (so it’s not intended to be a definitive reference covering all the nuances), still, it does make the clear distinction between above-ground and below-ground conductors to try and get people to think about there being TWO differing purposes that an identical-sized conductor can have i.e. to either leak current (into the geology) or to transfer it (equipotn)… or a combination of both – Oh, that’s 3 but hey. So, for the sake of simplicity, it might be better to leave coatings for another blog 😉

Earth Mats | Earth Plates | Earth Rods | Earth Bars | Earth Tapes | Exothermic Welding from T&D, The Earthing Equipment & Lightning Protection Eqpt. Distributors