Thorne & Derrick International distribute the complete range of Nexans Euromold Connectors for all types of medium/high voltage electrical bushings including Interface A according to CENELEC EN 50180 and 50181. Complete supporting range of medium/high voltage cable accessories including Euromold elbow connectors, straight connectors, straight plugs and surge arresters are available for bushing Interface A equipment.
➡ For further information about Euromold Connectors for all other Interface Bushingsplease see the following information:
Switchgear ♦ Transformers ♦ Motors ♦ Joint ♦ Terminate ♦ Connect ♦ Cables ♦ MV HV Bushings ♦ 11kV 33kV Medium & High Voltage
Thorne & Derrick International
11kV 33kV Terminations
T&D are Main UK Distributors for Nexans Power Cable Accessories – this includes heat shrink and cold shrink cable joints and terminations and the Euromold range of screened separable connectors extensively installed to terminate MV-HV power cables.
Images Courtesy: Murray Jones (Specialist Trainer, Transmission Lines & Rigging)
Application: Portable Earthing Overhead Line Distribution Networks
Voltage: 275kV Extra High Voltage (EHV)Â
Uploaded by Chris Dodds – reading time 3 minutes
Portable Earthing
In this high-wire act the overhead linesmen are shown using Portable Earthing Kits on 275kV overhead power distribution and transmission lines – the portable earths are installed and connected using Insulating Sticks.
Electrical Safety For Overhead Lines & Substations
Thorne & Derrick International are the UK’s leading stockist and supplier of the CATU Electrical range of Electrical Safety Equipment – protecting utility workers including jointers, splicers and linesmen exposed to the risk of electrocution and arc flash hazards.
A complete range of HV Sticks are available for use on 33kV/40kV, 66kV/90kV and 275/400kV underground cables and overhead lines with a selection of short circuiting and portable earthing kits and associated high voltage earth clamps for substation busbars or line conductors. Insulating sticks are available as telescopic and extendable suitable for outdoor use or supplied as fixed length sticks.
The following tables provides an overview of Portable Earthing Kits available from CATU Electrical, The Electrical Safety Specialists – comprehensive range of earthing clamps are available for MV-HV substation, power cables and overhead conductors.
Medium & High Voltage Substation Portable Earthing KitsÂ
♦ Portable earthing kits used with CATU CF-5-40-E insulating stick (up to 40kV) – generally used to provide short circuiting and earthing on power systems operating at 11kV/33kV.
Portable Earthing & Short Circuiting Kits
Portable Earthing Kits Overhead Line Conductors & Cables
♦ Portable earthing kits used with CATU CE-4-21-C insulating stick (up to 90kV) – – generally used to provide short circuiting and earthing on power systems up to 66kV.
All following images courtesy: Murray Jones.
Tower transfer to allow for structural work to high voltage overhead lines
Hanging 600mm rollers to tension string OPGW using existing earth wire as the draw wire
Application: Connection & Termination Of 33kV Cable Into MV Siemens GIS
Cable Connector Type: Nexans Euromold Interface C Bushing Connector
Cable Connector Part Code: Euromold (M484TB/G-32-95.240UN5+KIT)
Cable Type & Manufacturer: Prysmian 33kV XLPE Single CoreÂ
Cable Jointer: Daniel Croft
by Chris Dodds T&D – estimated reading time 5 minutes
Dan is currently IAC Cable Installation Engineer Nordsee Cluster for Nordsee Two GmbH
Euromold Connectors
Today, we welcome Dan Croft onto our Jointers Blog to demonstrate the skill level and competency required to terminate 33kV cables into gas insulated switchgear manufactured by Siemens using Euromold Connectors.
The medium voltage power cable manufactured by Prysmian is expertly prepared by the 33kV Competent Cable Jointer using precision engineered and professional cable jointing tools – the 33kV Prysmian cable was stripped and prepared using the following;
Daniel explains the Euromold connector installation, “the 33kV copper earth screen is bonded to the outer sheath so a window needs to be taken out with Kevlar string, a bit of heat and a tool such as a flat head screwdriver. Used very carefully and precisely in order to remove the window without damaging the screen underneath. Also, all MV cable preparation work such as stripping of bonded screen and XLPE insulation removal must be conducted to the highest possible standard – this includes sanding and polishing of the XLPE insulation layer to ensure there is a “super smooth” and unblemished surface. This is achieved by the cable jointer using precision shaving techniques then sanding (with 240,320 and 400 grit sandpaper sheets). Finally, the 33kV cable insulation is polished with super fine paper and carefully heated creating a surface as smooth as glass. The 33kV cable is then ready to terminate using the Euromold connector type dependent upon the medium or high voltage equipment Bushing Interface type.”
âž¡ Euromold connectors are available in Interface A-F specifications to terminate MV-HV cables into switchgear, transformers and substations including up to 66kV connections.
33kV Cable
33kV Cable Specification. The medium/high voltage power cable specification is 33kV single core XLPE insulation with 240sqmm aluminium conductor and copper tape screen – the semicon screen layer is fully bonded to XLPE. Also the cable sheath has an additional fully bonded semicon layer. The cable sheath has a semi-conductive later bonded to it which needs removing for electrical separation between the copper earth tape and outer sheath.
33kV Connectors. 33kV cables are terminated using Nexans Euromold Connectors and connected into the electrical equipment to create a “touch-safe” screened MV cable termination into the gas insulated switchgear.
Flashguard Installed.Arc free and arc flash protection solution for MV Power Distribution Electrical Equipment – the physical barrier stops the MV-HV connectors or terminations becoming free from the switchgear or transformer bushing in the unlikely event of a fault.
Thorne & Derrick International
Should you require any assistance with the selection or specification of Prysmian cable joints please do not hesitate to contact us.
T&D distribute the most extensive range of MV & HV Cable Joints & Terminations, Cable Installation Accessories & Cable Pulling Equipment – we service UK and international clients working on underground cables, overhead lines, substation earthing and electrical construction at LV, 11kV, 33kV and EHV transmission and distribution voltages.
This following procedure from TransGrid supports the Power System Safety Rules and its requirements for Portable Earthing assembled under:
Making High Voltage Apparatus Safe for Work – Category 5.5; &
Making Overhead Lines Safe for Work – Categories 6.4, 6.5
The following describes Electrical Safety Equipment manufactured by CATU Electrical which has been approved for portable earthing of high voltage electrical conductors. This procedure also includes methods for checking substation and overhead line earthing equipment along with inspection and maintenance procedures.
Date of Issue: 26 May 2016Â
Portable Earthing Leads & Systems
An earthing system is a recognised set of components to perform the function of portable earthing for medium/high voltage cables. The components are assembled into either polyphase earthing systems (usually three phase) or single phase earthing systems.
A portable earthing leads and system comprises of:
1. Line End Clamp or Clamps
2. Portable Earthing Leads
3. Earth End Clamp or Clamps
4. Short Circuiting Point (Trifurcating Plate)
5. Connecting Hardware
6. Insulating Sticks
Portable Earthing Leads & Kits manufactured by CATU Electrical are for short-circuiting of medium/high voltage power cables and conductors including 11kV/33kV and 132kV.
Prior to the issue of an Access Authority, appropriate earths must be applied to High Voltage Equipment. These are referred to as Access Authority earths under the Power System Safety Rules. Where fixed earthing switches are either not available or not suitable for the planned work, portable earths may be used. Such portable earths can be applied to:
overhead tranmission lines
substations
switchboards
underground cables
The objective of Portable Earthing Equipmentis to provide a pathway for unanticipated electrical current to flow safely to earth. The current flowing through the earth causes protection systems to operate, tripping circuit breakers and so removing the source of electrical power supply.
The earthing equipment described in this procedure has been designed and tested for use with standard TransGrid conductors and fittings such as stirrups and stubs.
Electrical Safety
Electrical safety guidance about handling portable earthing equipment in substations or near transmission lines:
1. Always carry earthing equipment below shoulder level
2. Ensure that clamps and leads are kept a safe distance from any high voltage conductor
3. Assemble and inspect earthing equipment on the ground
4. Extend or prepare any earthing equipment such as shot gun sticks on the ground
CATU Electrical – Thorne & Derrick are the largest UK stockist and supplier of MV HV Electrical Safety Equipment for Substations & Overhead Lines
Portable Earths
Applying Portable Earths
Do not allow any part of the earthing system to encroach on safe approach distances.
1. Where practicable keep the portable earthing leads away from the body
2. Apply earth clamps to stirrup (if provided) or a horizontal conductor where possible
3. Avoid earth clamp application to bushing caps and to braids and
4. Position earth clamp so that tension on the earth lead is minimised
Removing Portable Earth Leads
Earthing equipment is to be removed carefully from high voltage conductors to prevent the equipment encroaching on or coming into contact with adjacent live high voltage conductors.
Discharging HV High Voltage Equipment
Where an electrical circuit could potentially discharge through the earthing system, sufficient time must be allowed between the de-energising of the high voltage conductors and the application of the portable earthing system to permit residual charge to be dissipated.
Equipment Experiencing A Fault
Any medium voltage or high voltage portable earthing equipment for overhead line or substation applications that experience a fault or over current shall be withdrawn from service immediately.
Rating
Check that the rating of the earthing equipment is appropriate for the fault level at the location at which it is to be applied. The equipment used for earthing shall have a fault withstand rating greater than that of the location in which it is used.
Information about the expected fault currents and back-up protection times at particular locations is available from System Operations staff.
Where the fault rating of the location exceeds that of the equipment, multiple earthing sets may be used to increase the rating of the earthing system:
1. In switchyards this information will be included on the High Voltage Preparation and Restoration Instruction (HVPRI);
2. On transmission lines where the fault rating of the line exceeds the fault rating of the earthing set, multiple sets of CATU MT815S earth clamps and associated earth end clamps may be used.
Equipment & Connections
Check that the earthing system is complete, i.e. that all earthing components are present.
Check that all bolted connections are tight and that any electrical connection is positive and mechanically sound. Ensure that earthing leads are sufficiently long for the proposed task.
Inspect For Damage
Ensure that the MV-HV earthing leads and equipment is in a serviceable condition. Any portable earthing equipment found to be defective shall be removed from service for repair.
Connect Earths To Earthing End Point
Connection at the earth end point shall be performed prior to any connection to a conductor.
Use Of The CATU MT-815S Clamp
The CATU MT 815S earth clamp is applied to and removed from conductors using a ‘shotgun’ application stick of appropriate length. Once the clamp is placed onto the apparatus to be earthed, the shotgun stick is removed.
Use Of The CATU MT-815E Clamp
The CATU MT 815E earth clamp is applied to and removed from conductors using the attached CATU CM4130-E insulating sticks.
Use Of The CATU MT-701 Clamp
The CATU MT-701 clamp is a V-shaped cast aluminium earth clamp that maintains contact with the conductor via a spring loaded jaw that is preset by a latching mechanism. The clamp is ‘snapped’ onto the conductor by a quick pulling action that triggers the jaw mechanism. The clamp is designed to be applied to and removed from medium/high voltage conductors using haulage and release cords.
Arming The CATU MT-701 Clamp
Lay the clamp on the ground so that the tail of the tongue points vertically upwards.
Holding the earth lead in one hand to stabilise the clamp, use the heel of your shoe to compress the tongue down against the body of the clamp until it latches. Ensure that the clamp is securely latched before handling.
Applying The CATU MT-701 Clamp
1. Pass the haulage cord over the conductor or through the stirrup by the using a sandbag
2. Arm the earth clamp
3. Hoist the clamp to the conductor using the haulage cord; then
4. Latch the clamp to the conductor with a quick pull on the cord
Removing The CATU MT-701 Clamp
1. Take the weight of the CATU clamp and lead on the haulage cord
2. Pull the release cord until the clamp releases from the conductor
3. Lower the earth clamp and lead/s on the haulage cord; and
4. Pull the haulage cord over the conductor or through the stirrup
Portable Earthing For Switchyards
Connection To Earth End Point
Earthing stubs shall be used for all earth end connections within medium/high voltage switchyards and these are generally installed on structures in the area where it is normally necessary to apply portable earths. It is important to ensure that the stub is not corroded and that it is securely mounted on the structure. Only use the CATU MT-815S clamps with earth stubs. At the earth end, the CATU MT-815S clamp can be applied with a CATU insulating stick or the CATU MT-815S application handle.
Portable Earthing Leads For Overhead Lines & Transmission
Connection to Earth End Point on Steel Tower Overhead Lines
For steel tower earthing systems, the tower itself is used as the earth point. CATU MT-847 surface penetrating clamps shall be used on painted or galvanised surfaces. When applying earth end clamps to a steel tower the clamps should be attached to a flat part of the tower structure and screwed up as tightly as practicable by hand.
Connection to Earth End Point On Wood Or Concrete Pole Overhead Lines
Pole earthing systems involves the use of both the pole earth and an independent temporary earth electrode (earth stake). The earth stake is to be positioned approximately 1.3m from the pole and driven 600mm into the ground then bonded to the pole earth using a standard portable earth lead with either CATU MT-815S clamps applied with a shotgun stick or MT-815S application handle
Portable Earthing For Switchgear
In general, indoor medium/high voltage switchgear is provided with manufacturers specific portable earthing systems. However, the dedicated earthing system provided maybe inadequate or non-functioning. The application of portable earthing systems in indoor switchgear situations is usually limited by physical clearances. The choice of MV-HV earthing system used will therefore be determined by the geometry of the switchgear involved and the practicality of applying the available portable earthing equipment within restricted spaces. Any of the earth systems covered in this procedure, when used with earth clamps approved for indoor use, can be implemented in indoor situations.
The Bridge Method is commonly used where the fault rating of the indoor switchgear is less than or equal to the 25 kA 0.5 second rating.
Portable Earthing Using The Bridge Method
Connection To Earth End Point
Earthing stubs shall be used for all earth end connections and these are generally installed on structures in the area where it is normally necessary to apply portable earths. It is important to ensure that the stub is not corroded and that it is securely mounted on the structure. Only use the CATU MT-815S clamps with earth stubs. At the earth end, the CATU MT-815S clamp can be applied with a shotgun stick or the CATU MT-815S application handle.
Use Of The CATU MT815S Clamp On Medium & High Voltage Indoor Switchgear
Clamps can be applied to stirrups and conductors. In certain indoor switchgear situations, an ‘Earth Stub’ may have been installed on the bus bar or conductor to enable the application CATU MT-815S clamps.
Use Of The Pfisterer 360333333 Clamp On Indoor Medium & High Voltage Switchgear
Known as universal angle clamps these are applied to ball stubs using a CATU CM710 E application handle. Once the earth clamp is placed onto the apparatus to be earthed the application handle is removed.
Portable Earth Clamps with Pfisterer 360333333
Portable Earthing Situations
Line End Clamps
Earth End Clamps
Reference
Connection
CATU Clamp
Application
Connection
Clamp
Application
Conductors In Substations
Earthing Stirrup
MT815S
Shotgun Stick
Earth Stub
Screw Action Clamp MT815S
MT 815S Application Handle
Application of Portable Earthing In MV HV Switchyards
Conductor
MT-701
Haulage & Release Cord, Sandbag, HV Operating Rod
Steel Tower Overhead Lines
Conductor
MT815S
Shotgun Stick
Tower Structure
Surface Penetrating Clamp
By Hand
Application of Portable Earthing On Overhead Transmission Lines
Connection To Earth End Point On Steel Tower Overhead Lines
MT815E
CATU CM-4130-E Application Stick
MT-701
Haulage & Release Cord, Sandbag, HV Operating Rod
Wood & Concrete Pole Overhead Lines
Conductor
MT815S
Shotgun Stick
Earth Stake
Screw Action Clamp MT815S
MT 815S Application Handle
Application of Portable Earthing On Overhead Transmission Lines
Connection To Earth End Point On Wood Or Concrete Pole Overhead Lines
MT815E
CATU CM-4130-E Application Stick
MT-701
Haulage & Release Cord, Sandbag, HV Operating Rod
Indoor Switch Gear
Conductor
MT815S
Shotgun Stick
Earth Stub
Screw Action Clamp MT815S
MT 815S Application Handle
Application Of Portable Earthing On Indoor Switchgear
Ball Point
Universal Angle Clamps
CM710E Application Stick
Mobile Plant
Earth Stub On Mobile Plant Chassis
MT815S
MT 815S Application Handle
Earth Stub
Screw Action Clamp MT815S
MT 815S Application Handle
Mobile Plant In The Vicinity Of High Voltage Conductors
Mobile Plant Chassis Or Boom
Surface Penetrating Clamp
By Hand
Earth Stub
Screw Action Clamp MT815S
MT 815S Application Handle
Tower Structure
Surface Penetrating Clamp
By Hand
Earth Stake
Screw Action Clamp MT815S
MT 815S Application Handle
Screw Action Clamp – CATU MT815S
Approved Rating
40kA/0.5 seconds
Use
Line or Earth end connections for Earthing, Bonding & Bridging
Limitations of Use
Round Conductor up to 44mm in diameter, Flat Conductor from 3mm to 40mm in thickness
Drawing Number
STD-647175
Stockcode
3180437
Associated Equipment
Shotgun Stick or Hand Application Tool
Screw Action Clamp – CATU MT815E
Approved Rating
25kA/0.5 seconds
Use
Line end connections for transmission line earthing
Limitation of Use
Round Conductor up to 44mm in diameter
Drawing Number
–
Stockcode
–
Associated Equipment
CATU CM-4130-E application stick
Universal Angle Clamp – Pfisterer 360 333 333
Approved Rating
40kA/0.5 seconds
Use
Line end connections for Indoor Earthing
Limitations of Use
Haymarket 11kV
Drawing Number
–
Stockcode
Not Stocked
Associated Equipment
CM 710 E application stick
Snap Action Line Clamp – CATU MT-701
Approved Rating
40kA/0.5 seconds
Use
Line end earthing connections only
Limitations of Use
Round Conductors 20 to 40mm diameter
Drawing Number
STD-197006
Stockcode
986968 ea
986901 complete set with single leads
986893 complete set with twin leads
CATU CM 710 E Insulating Sticks
Approved Rating
Not applicable
Use
Haymarket 11kV Indoor
Limitations of Use
Must be used only with Pfisterer 360 333 333
Stockcode
Not stocked
Associated Equipment
Pfisterer 360 333 333 clamp
CATU CM 4130 E Insulating Sticks
Approved Rating
Not applicable
Use
Insulating stick for line end connections for transmission line earthing
Limitations of Use
Must be used only with CATU MT815E clamps
Stockcode
–
Associated Equipment
CATU MT815E clamps
Glossary
Term
Definition
Earth Stake
A steel rod driven into the ground to provide an earth point for portable earthing equipment
Earth Lead
A yellow flexible cable that connects the conductors of equipment required to be earthed through clamps or other means to the general mass of the earth
Bridging
The process of placing a conductor (or bridge) across a break in an electrical circuit (HV conductor, neutral or earthing system) in order to maintain electrical continuity
Fault Current
Abnormally high current that flows due to partial or complete failure of insulation at one or more points
Earthing System
A group of components that performs a short circuiting or earthing function
Earthing Equipment
Any piece of equipment for the purpose of earthing, either individually or combination
Line End
That part of an earthing set connected to conductors or other apparatus that may be energised
Earth End
That part of an earthing set connected to the general mass of earth directly, or through an “earthed” piece of equipment e.g structure or earth grid
Trifurcating Plate
An aluminium plate used to connect the earthing leads and provides a short circuiting point for the phases
Screw Action Clamp
A clamp in which the mechanism of attachment to conductors is carried out by a positive screw thread
Snap Action Clamp
A clamp by which attachment to the conductors is carried out by a spring operated mechanism
Haulage & Release Cord
Associated with snap action clamps, enables the clamp to be hauled up and applied to the conductor to be earthed
Trifurcated Earthing System
Single Phase, Single Lead Earth System
Single Phase, Twin Lead Earth System
Substation Earthing
Thorne & Derrick International distribute ABB Furse and AN Wallis Earthing & Lightning Protection Systems for the protection and grounding of Medium, High & Extra High Voltage Substations – this includes copper earth tapes, earth rods, copper earthing plates, clamps and ancillary items for 33kV, 66kV, 132kV and 275kV substations. For more information please see substation earthing.
T&D distribute the most extensive range of LV, MV & HV Cable Jointing, Terminating, Installation & Cable Pulling Equipment – we service UK and international clients working on underground cables, overhead lines, substation earthing and electrical construction at LV, 11kV, 33kV and EHV transmission and distribution voltages.
Alroc Cable Jointing Tools for MV and HV Power Cables
Alroc manufactures specialist cable jointing tools for the accurate preparation of low, medium and high voltage power cables.
Correct cable preparation is essential for reliable cable joints and terminations. Therefore, professional cable jointers use precision tools to remove insulation and semiconductive screens without damaging the underlying cable components.
One example is the Alroc CAMF4/40-90-BBCF. This multifunction tool removes bonded semiconductive screens and XLPE insulation from medium and high voltage cables.
In addition, its adjustable design supports several preparation operations using a single tool.
Alroc CAMF4/40-90-BBCF Technical Specifications
The CAMF4/40-90-BBCF is designed for cable preparation across a specified diameter range.
What Is Arc Flash PPE and Why Is It Important? Arc flash PPE is specialist personal protective equipment designed to help protect electrical workers against the thermal hazards of an electric arc. It includes arc-rated clothing, protective helmets, face...