Flame Retardant Optical Fibre Cable, AICI-I/O/RM/C-W, MUD PROTECTED
Prysmian Draka Offshore Cables – LV, MV & HV Flame Retardant Optical Fibre (RFOU BFOU to IEC / NEK 606)
Prysmian draka cABLES
AICI-I/O/RM/C-W, MUD PROTECTED Cable
Fire Retardant Optical Fibre Offshore Cables
Flame Retardant Optical Fibre Cable, AICI-I/O/RM-W, F6
The outer sheath is made from black UV-stabilized and weather resistant material which is SHF1 classified, and may be exposed for shorter periods to fluids such as diesel and mineral oils. The resistance to these fluids is according to IEC60811-2-1.
Prysmian Draka Offshore Cable Applications
Flame Retardant Optical Fibre Cable nek ts 606
Optical cable for industrial environments. The cable is suitable for both indoor and outdoor installation. Continiuous submergence in water is not recommended. Each fibre is colour coded for easy identification. The outer sheath is marked to show fibre type and cable type. An additional outer sheath is added for improved oil- and MUD protection. The outer sheath is DARK GREY.
Flame Retardant Optical Fibre Cable Core Identification
Fibre number | Colour | Fibre Number | Colour | Fibre Number | Colour |
1 | White | 9 | Violet | 17 | Blue + marker |
2 | Red | 10 | Turquoise | 18 | Grey + marker |
3 | Yellow | 11 | Orange | 19 | Brown + marker |
4 | Green | 12 | Pink | 20 | Light Blue + marker |
5 | Blue | 13 | White + marker | 21 | Violet + marker |
6 | Grey | 14 | Red + marker | 22 | Turquoise + marker |
7 | Brown | 15 | Yellow + marker | 23 | Orange + marker |
8 | Black | 16 | Green + marker | 24 | Pink + marker |
Flame ReTardant Optical Fibre Cable Properties
Tensile Strength (IEC 60794-1-2E1) | |
Max tensile load during installation | 1700 N |
Max tensile load during operation | 750 N |
Crush (IEC 60794-1-2E3) | 2000 N/10cm |
Impact (IEC 60794-1-2E4) | 1 impacts, 25J |
Torsion (IEC 60794-1-2E7) | ±1 turn/1m |
Cable Bending | |
Minimum bending diameter | 15x outer diameter |
Cable bend (IEC 60794-1-2E11) | <0.5dB/ ±5 turn |
Flexibility (IEC 60794-1-2E8) | 1000 cycles |
Temperature Window | |
Operation | 40°C to +70°C |
Installation | -10°C to +70°C |
Storage | 40°C to +70°C |
Water tightness* (IEC 60794-1-2F5B) | < 3 m/24 hours |
Chemical Resistance | |
Mineral oils IRM 902 (IEC60811-2-1) | – 7 days /100°C |
Diesel – IRM 903 (IEC60811-2-1) | – 7 days /100°C |
Fire & Smoke Classifications | |
IEC 60332-1 | |
IEC 61034 | |
IEC 60332-3-22 (Cat. A) | |
IEC 60332-3-24 (Cat. C) | |
IEC 60754-1 | |
IEC 60754-2 |
Cable Joints, Terminations, Glands & Cleats – available for 6.6kV 11kV and 33kV medium voltage (MV) power cable
T&D distribute the complete range of Prysmian cable cleats, cable joints and cable glands for onshore and offshore LV-HV power, control and instrumentation cables.
Call T&D for Prysmian Draka Cables NEK 606/BFOU/RFOU/BU/RU