Halogen-Free, Mud Resistant, Fire Resistant Instrumentation Cable BFOU(c) 150/250(300)V, S4/S8

Prysmian Draka Offshore Cables – LV, MV & HV Instrumentation (RFOU BFOU to IEC / NEK 606)
Prysmian draka cABLES
BFOU(c) 150/250(300)V Cable
MGT/EPR/EPR/TCWB/EVA Offshore Cables
Operating Temperature : 90°C
Operating Voltage : 150/250(300)V
Prysmian Draka BFOU Offshore Cable Applications
Instrumentation Cable nek ts 606
Fixed installation for instrumentation, communication, control and alarm systems in both EX (hazardous area Zone 0, 1 & 2) and safe areas, emergency and critical systems where requirement for fire resistance exists . The cable meets the mud resistant requirements in NEK TS 606:2009.
Instrumentation Cable Core Identification
- Pair – Black – Light Blue
- Triple – Black – Light Blue – Brown
- Quad – Black – Light Blue – Brown – Grey
| BFOU Instrumentation Cable Construction | Code Letter | BFOU Instrumentation Cable Description |
| Conductor | Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 | |
| Insulation | B | Mica-tape + EP-rubber, IEC60092-360 (EPR) |
| Pair / Triple / Quadtwisting | Color coded cores twisted together and wrapped with polyestertape. Pairs/Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drainwire. Pairs/triples are identified by numbered tape or by number sprinted directly on the insulated conductors | |
| Inner covering | F | Flame retardant and halogen-free thermoset compound |
| Tape over inner covering | PET tape | |
| Cable armour/screen | O | Tinned annealed copper wire braid |
| Tape over armour/scree | PET tape | |
| Cable outer sheath | U | Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360) |
| Marking text | Eg. “meter” “year” DRAKA 01 BFOU(c) 250V S4/S8 4 PAIR 0,75 mm² FLEX – FLAME IEC 60092-376 IEC 60331-1*) or IEC 60331-2*) IEC 60331-21**) IEC 60332-3-22 | |
| Cable manufacturing unit | DRAKA 01 = Draka Norsk Kabel (Prysmian Group) | |
| Outer sheath colour | Grey or blue |
Cable Standards Applied

Cable Joints, Terminations, Glands & Cleats – available for 6.6kV 11kV and 33kV medium voltage (MV) power cables.
- IEC 60092-376 (2003-05) – Design IEC 60228 class 2 – Conductor
- IEC 60092-360 – Insulation IEC 60092-360 – Sheath
- IEC 60332-1-2 – Flame Retardant
- IEC 60332-3-22 – Flame Retardant
- IEC60331-1,-2,-21 – Fire Resistant
- IEC 60754-1,2 – Halogen Free
- IEC 61034-1,2 – Low Smoke

T&D distribute the complete range of Prysmian cable cleats, cable joints and cable glands for onshore and offshore LV-HV power, control and instrumentation cables.