Hydro Carbon Fire Resistant Instrument Cable BFOU-HCF(i) 150/250(300)V, S15
Prysmian Draka Offshore Cables – LV, MV & HV Instrumentation (RFOU BFOU to IEC / NEK 606)
Prysmian draka cABLES
BFOU-HCF(i) 150/250(300)V Cable
MGT/EPR/EPR/TCWB/EVA/HCF/SHF1 Offshore Cables
Operating Temperature : 90°C
Operating Voltage : 150/250(300)V
Prysmian Draka BFOU Offshore Cable Applications
Instrumentation Cable nek ts 606
Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for hydrocarbon fire resistance is vital.
Instrumentation Cable Core Identification
- Pair – Black – Light Blue
- Triple – Black – Light Blue – Brown
BFOU-HCF Instrumentation Cable Construction | Code Letter | BFOU-HCF Instrumentation Cable Description |
Conductor | Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 | |
Insulation | B | Mica-tape + EP-rubber, IEC 60092-360 (EPR) |
Pair / Triple / Quad twisting | Color coded cores twisted together. Pairs/Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair/triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples are identified by numbered tape or by numbers printed directly on the insulated conductors. | |
Inner covering | F | Flame retardant and halogen-free thermoset compound |
Tape over inner covering | PET tape | |
Cable armour/screen | O | Tinned copper wire braid |
Tape over armour/scree | PET tape | |
Cable outer sheath | V | Flame retardant, halogen-free and oil resistant thermoset compound (Therban), SHF2 (IEC 60092-360) |
HCF Protection | – HCF | Extruded heatblock compound |
Tape | Lapped glassfibre tape | |
Cable outer sheath | Flame retardant, halogen-free thermoplastic compound, SHF1 (IEC 60092-360) | |
Marking text | Eg. “meter” “år” DRAKA NORSK KABEL BFOU-HCF(i) 250V S15 4 PAIR 1,5 mm² HCF 1100/30 FLEX – FLAME IEC 60331-21 IEC 60332-3-22 | |
Outer sheath colour | Grey, Blue or Black |
Cable Standards Applied
Cable Joints, Terminations, Glands & Cleats – available for 6.6kV 11kV and 33kV medium voltage (MV) power cables.
- IEC 60092-376 (2003-05) – Design IEC 60228 class 2 – Conductor
- IEC 60092-360 – Insulation IEC 60092-360 – Sheath
- IEC 60332-1-2 – Flame Retardant
- IEC 60332-3-22 – Flame Retardant
- IEC 60331-21 – Fire Resistant
- EN 1363-2 / ISO 834 – HC Fire resistance
- IEC 60754-1,2 – Halogen Free
- IEC 61034-1,2 – Low Smoke
- Draka Norsk Kabel – HCF protection
T&D distribute the complete range of Prysmian cable cleats, cable joints and cable glands for onshore and offshore LV-HV power, control and instrumentation cables.
Call T&D for Prysmian Draka Cables NEK 606/BFOU/RFOU/BU/RU