
The following list is the current ranges of Nexans Connectors which are currently ATEX Certified for the safe termination and connection of medium/high voltage power cables into potentially explosive atmospheres designated as Zone 1 or Zone 2 according to the explosion risk – the following type products are all the Euromold brand of screened separable connectors and are used to terminate cables with polymeric insulation (XLPE EPR) into MV-HV Electrical Equipment located onshore or offshore.
Euromold
Cable Connectors for 11kV 33kV Cables In Hazardous Areas
Nexans connectors currently listed and certified according to ATEX Hazardous Area Directive:

K400TB(/G)
K430TB(/G)
K440TB(/G)
K676LRA(/G)
K300PB
300SA
400PB-XSA
K675BE
K400AR-3
K400AR-4
400A-24B
K400CP-SC
K440CP
K670AR-2
K672T1
K672TBC

Cable Connectors
K680CP
K484TB
K804PB
800SA
K944TB
K400AR-6
K900AR-1
K900AR-2
K900AR-3
K900AR-4
K480TB(/G)
K489TB(/G)
K800PB(/G)
K809PB(/G)
K400BE
K480BE
K784TB(/G)
K909TB(/G)
K909PB(/G)
K900BE

Nexans Connectors – Connect & Terminate Cables Into Switchgear & Transformers In Hazardous Areas | 11kV 33kV – for further info visit Screened Separable Connectors
Joints & Terminations For Cables
In Hazardous Area Locations
Thorne & Derrick distribute MV-HV Joints & Terminations specified for use with power, control and instrumentation cables installed in hazardous areas where the risk of igniting the “Fire Triangle” precludes the use of naked flames and therefore heat shrink terminations or joints – manufactured from silicone rubber housing the Nexans AIN range of cold-applied cable accessories are slip-on terminations which do not require the application of naked flames to activate heat-shrink tubings.
Specially developed cable accessories including cable joints with resistance to aggressive hydro-carbons, flame and fire are available – standard resin cable joints already installed in hazardous area locations which require protection against potential fire can be over-wrapped with fire protection blankets to achieve fire resistance to the cable according to IEC 60331-11 & 21.
➡ ATEX Cable Joints – Jointing Cables In Hazardous Areas Zone 1 & Zone 2
➡ ATEX Cable Glands – Glanding Cables In Hazardous Areas Zone 1 & Zone 2
Nexans Connectors
Nexans Connectors terminate MV & HV Cables, typically 11kV 33kV 66kV voltage classifications, into electrical equipment distributing medium/high voltage power – the connectors terminate cable onto all types of MV-HV equipment bushings in industrial applications and as outlined above for use in potentially explosive atmospheres.


Images: David Baldock (HV Cable Jointer)
11kV Terminations
Prior to the installation of MV-HV cable accessories whether it be heat shrink, cold shrink or separable connectors, it is critical that careful and accurate semicon workmanship is achieved by the Jointer. The treatment and cut of the semicon screen by the 11kV jointer is essential to the stability and service of all joints, terminations and connectors on 11kV/33kV power systems.
The above cable preparation images clearly shows the straight and clean cut to the black semicon screen stepping down onto the 11kV cable insulation (XLPE) – here a constant force spring provides a straight edge for copper tape screen on the 11kV cable before installing the cable termination.
Semicon cutback has been enabled by the innovation and development of dedicated cable jointers tools which should provide precision engineered cable preparation.
However, jointers tools alone without the knowledge, expertise and skill of a Competent Jointer to use them are not worth diddly squat.
For instance the photograph below highlights the problem of unskilled labour, even if equipped with the correct cable jointing tools, inflicting catastrophic damage to MV-HV power systems through lack of training, experience and understanding of the criticality of semicon cutback.
Non-radial, rough and jagged semicon screens with protuding points at the cutback will cause cable termination or joint failure. Outage. Blackout.

Meet The Cable Jointer
David Baldock is an experienced LV-HV cable jointer up to and including 33kV specialising in electrical cable installation and repair to medium/high voltage power cables including XLPE, PILC, PILC/SWA, PICAS and EPR. Ranging in cable sizes from 25sqmm to 800sqmm and covering single cores to 3 cores with copper tape screen and wire screen.
Qualified and Competent to carry out all MV-HV cable terminations such as Tyco-Raychem, Nexans, Pfisterer, 3M, Euromold and ATEX Euromold cable terminations covering all heatshrink and cold shrink terminations.
➡ The Semicon Screen – A Most Critical Point In Any MV Cable Joint, Termination Or Connector – Read Blog
11kV Terminations, Joints & Connectors
Thorne & Derrick are national distributors of Cable Installation, Jointing, Substation & Electrical Safety Equipment MV HV – we service UK and global businesses involved in cable installations, cable jointing, substation earthing, overhead line and electrical construction at LV, 11kV, 33kV and EHV.

Joint | Terminate | Connect Medium & High Voltage Cables MV HV

Invitation
Thorne & Derrick invite you to join LinkedIn’s largest LV-HV Electrical Discussion Group : Low & High Voltage Power, Cabling, Jointing & Electricals.
Discussion subjects include cable installations, cable jointing, substation, overhead line and electrical construction at LV, 11kV, 33kV and EHV. Network, engage and promote your profile, company or products with over 10,000 influencers.


Thorne & Derrick | Cable Pulling & Laying Equipment Stockists and Suppliers
Cable Pulling
The following information based upon a document produced by UK DNO, Scottish & Southern Electricity Networks, provides information and guidance on New Connections and best practise for cable pulling and laying and when installing LV (Wavecon | Concentric), 11kV (3 Core | Single Core) and 33kV (Single Core) cables into underground cable trenches.
The cable pulling equipment for ensuring safe and compliant installation of LV-HV cables up to 33kV is briefly outlined – should you require any further information or technical support please contact us.
All work carried out and cable pulling equipment used must be compliant with SSE technical guidance (TG-PS-881) available from the SSEN website.
It is also recommended that contractors and clients review the ‘Practical Guide to Streetworks’ before undertaking any excavations prior to installing LV-HV cables to form part of new connections.
The following cable trench section shows the position of cable and the cable duct in the ground – it is important that the top of any apparatus is at these depths as a minimum, this includes the top of the cable duct. In addition to the cable or duct there is a requirement for 75mm finefill material on all sides. Cable marker tape or cable tiles/covers must be installed 150mm above the top of the apparatus, this needs to have SSEN branding on.

This table shows the minimum depths to top of apparatus (A within the diagram above)
| Minimum Apparatus Depth |
Unmade Ground, Verges & Footway (mm) |
Carriage (Road) (mm) |
Agricultural (mm) |
| Cables LV |
450mm |
600mm |
1000mm |
| 11kV Cables HV |
600mm |
750mm |
1000mm |
| 33kV Cables HV |
800mm |
900mm |
1100mm |
Minimum Excavation depth required = (A) minimum depth of apparatus + (B) outside duct/cable size + (C) 75mm of sand bedding.
Please note that (M) represents the cable marker tile (for 33kV cables use Stokbord covers) or cable protection tape for all other installations including 11kV cables and cable joint protection.
Please note: Where there are sudden changes in surface type (e.g footway to carriageway), excavations should always be at the greater of the depths required.

New Housing Service Cable Installation Guide
Experience has shown that by using a service tube the disturbance to the site is reduced when the electricity supply is connected.
The service tube can be laid in the same cable trench as the other services are shown, with an identifying plastic cable marker tape installed above to give advanced warning of service cable location on private property.
External meter cabinets
The external meter cabinets must be positioned in agreement with SSE to provide unrestricted access.
The preformed ‘hockey sticks’ can be installed either within the cavity or clipped to the outer surface of the wall below the meter cabinet.
White ‘hockey sticks’ must be used on the outer surface of walls. The service tubing must be securely coupled to the ‘hockey sticks’. The cabinets are only large enough to house SSE service and connection equipment.
Clients must fit own main switches on an inside wall so that the length of interconnecting cable does not exceed 3 metres.
This cable must only enter through the bottom of the cabinet, using the right hand hole, when viewed from the front.

Typical Cross Section of A Service Trench

Duct Seals – contact us for duct sealing solutions and products to provide sealing against water (flood prevention) to copper and ducted low, medium and high voltage power cables.
Installation of Cable ducts
For the installation of ducted schemes the use of Black electric cable ducts only (see table below for approved suppliers) are permitted for use.
Clients should consider the type of cable ducts intended to use before ordering as excavations will be different depending on which cable duct supplier you use – the minimum cable bending radius must also be considered by referring to the manufacturers specification and selecting the appropriate cable pulling equipment to include cable rollers, socks, drum jacks and cable winches.
Emtelle cable duct range includes a smooth bore type of ducts which have rigid preformed bends at differing angles. When pulling and laying cables it is important that angles or bends should not be placed too close together otherwise cable pulling tensions will become greater than the manufacturers guidelines during the installation process.
Winch Cable installation
All cable must be installed not exceeding the manufacturers recommended cable pulling tensions – this applies to low, medium and high voltage power cables. Contractors must familiarise themselves with these cable pulling loads before hiring the equipment to ensure that these loads are not exceeded.
For all Cable Pulling applications contractors should use the following cable laying equipment and products:
In addition to cable trench installations, for ducted cable schemes you will also need;
For 33kV single core cables it is recommended that the contractor put colour indicators on each cable for identification – the cable installer must securely anchor the cable drums and the cable winch at either end and ensure that the LV-HV cable does not come into contact that could inflict cable sheath damage.


Cable Socks – high tensile strength galvanised steel cable socks provide support and grip for LV-HV cable pulling into duct or laying into trench.
Cable Pulling Equipment
Cables, Duct, Duct Seals & Cable Tiles Approved Equipment
| Item |
Manufacturer |
Manufacturing Location |
Notes |
| LV Concentric Cables |
Tratos |
UK |
|
| Cabelte |
Portugal |
|
| LV Wavecon Cables |
Prysmian |
Wrexham UK |
|
| Hellenic |
Greece |
|
| 11kV Three Core Cables |
Nexans |
Hannover, Germany |
Aluminium stranded & solid conductors 11kV |
| Prysmian |
Wrexham UK |
|
| 11kV Single Core Cables |
Tele-Fonica Kable |
Poland |
Copper or aluminium stranded for all conductor sizes
Solid aluminium up to and including 300sqmm conductors 11kV |
| Prysmian |
Wrexham UK |
|
| Nexans |
Hanover, Germany |
|
| 33kV Single Core Cables |
NKT |
Cologne, Germany |
Copper or aluminium stranded for all conductor sizes 11kV or
Aluminum stranded for all sizes or solid aluminium up to and including 300sqmm |
| Tele-Fonica Kable |
Poland |
|
| Prysmian |
Wrexham UK |
|
| Nexans |
Hanover, Germany |
|
| Cable Duct |
Polypipe Civil Ltd |
UK |
|
| Emtelle UK Ltd |
UK |
|
| Cable Tile |
Centriforce |
UK |
|
| Cable Warning Tape |
Centriforce |
UK |
|
| Plastic Tape Tile |
Centriforce |
UK |
|
| Duct Seals |
TE Connectivity |
UK |
Rayflate Inflatable Cable Duct Seals |
| WT Henley |
UK |
Services Ducts (Green Plastic Compound) |
| Winn & Coates (Denso) |
UK |
Denso Mastic
Denso Tape |
| CSD Cable Sealing System |
UK |
CSD RISE Cable Duct Sealant System |

Joints | Terminations | Glands | Cleats | Cables | Tools | LV MV HV 11kV 33kV
Cable Laying & Pulling Equipment
Thorne & Derrick distribute an extensive range of Cable Laying & Pulling Equipment to enable the safe installation of utility power cables including LV Waveform and MV-HV Power Cables 11kV/33kV – full range of cable spiking tools available to ensure LV-HV power cables are dead prior to jointing or cable termination works.
➡ Further reading: Cable Pulling Equipment – A Cable Duct Laying Guide From BT Openreach

Thorne & Derrick | Cable Pulling & Laying Equipment Stockists and Suppliers
Cable Pulling
The following information produced courtesy of a BT Openreach document provides a quick guide to duct laying and the Cable Pulling Equipment required to install cables into underground cable ducting.
Where the Openreach cable duct crosses a carriageway adjoining kerbs must be temporarily marked to note positions. Openreach duct needs to be laid on an outer edge of the service trench to enable box building. The contractor will need to insert a draw rope through the duct and secure it to the marker posts at both ends of the crossing. The appropriate Plug Duct 4B socket end and 4C Spigot must be fitted.

PVC Cable Duct For Underground Telecom Cables | Openreach
Duct beneath a carriageway crossing must be laid at a depth of 600mm from the cover of the final surface levels. For engineering reasons (National Joint Utilities Group NJUG) it must be separated from other services laid in parallel by 600mm (to permit Openreach to install underground joint boxes without the need for bends). Cable marker no.2 is needed at the site entrance boundary to ensure link up identification for cable contractors.
The latest information on the positioning of utilities, mains and plants can be obtained from the National Joint Utilities Group.

Cable Ducting
- All cable runs must be laid as straight as possible for installation into duct using correct cable pulling equipment
- If required bend the cable ducts or use pre-formed duct bends supplied by Openreach
- There can be no more than one pre-formed 90° cable duct bend in any single run of duct
- Pre-formed 90° cable duct bends cannot installed in any duct linking two joint boxes
- Footpath or service strip ducting must be laid at 350mm depth of cover
- All space alongside the cable duct must be backfilled with granular fill to a minimum thickness specified by Openreach
- For all Single Dwelling Units (SDU) cable duct must be terminated on the external surface of the property
- The duct termination point shall be in a location that will allow unrestricted access for any future maintenance activity
- All cable ducts must be provided with a draw rope after installation, unless it’s agreed locally to substitute the draw rope with a cable
- Please notify the field based coordinator (FBC) when the duct has been laid and is ready for inspection.
Typical issues with carriageway road crossings
- Insufficient depth
- Proximity to other services
Impact of issues
- Renew duct – this may delay any first occupation date or subsequent occupation dates.
Avoiding Damage to the Openreach Underground Network
Openreach has an extensive underground network of ducted cables that can be located inside or on the perimeter of a site. The network is vulnerable to excavation related damage unless appropriate measures are taken. The precautions for avoiding damage to an underground utility plant are contained within the Health & Safety Guide No. 47: Avoiding Danger From Underground Services (download below).
This document stresses the need for available utility plans on site and the use of safe digging practices.
Third-party damage to the Openreach network can be expensive for that party to repair.
- Direct cost – the cost of repair
- Operational cost – delays associated with repair
- Social cost – loss of service to emergency services/centres or the vulnerable in society
💡 TIP: Use Openreach “Click Before You Dig” service – a proven record of minimising the potential for damage and cost.
If you locate damage on site you should contact your FBC immediately.
If outside the perimeter of your site and has the potential to be a danger to the general public please contact Openreach by calling 0800 023 2023, Option 1, Option 1.

Duct Seals – contact us for duct sealing solutions and products to protect and provide sealing against water (flood prevention) to copper and fibre ducted cables.
Cable Pulling Equipment
Thorne & Derrick distribute an extensive range of Cable Pulling & Laying Equipment to enable the safe installation of fibre and copper cables within the telecommunications industry. Safely installed cables reduces operational and maintenance requirements to the network and reduced service interruption to telecom cables, wires, ducts, cabinets and exchanges – products include cable spiking tools, conduit rods, cable lubricant, cable socks and rollers.
➡ Further reading: Cable Pulling Equipment – A Cable Laying, Duct & Installation Guide From SSE

Siemens – Gas Insulated Switchgear For Secondary Distribution MV Medium Voltage Power Systems Up To 33kV
Thorne & Derrick International, based in the UK, are a leading distributor of cable accessories and connection systems for 33kV cables – this includes heat shrink/cold shrink joints, terminations and EPDM type screened separable connectors manufactured by Nexans Euromold.
The following information enables the specification and selection of the correct 33kV cable plug type termination or connector to suit medium/high voltage power cables used with Siemens NXPLUS C Wind switchgear.
Specifically, we confirm the current approved 33kV cable connectors for use with Interface C 33kV Bushings on gas insulated switchgear.
33kV T Plug Type Cable Connectors
The following information table enables the selection and outlines the possible cable connection types (T-Plugs, Coupling Insert & Screened Separable Connectors) and MV surge arresters compatible with Siemens NXPLUS C Wind switchgear 33kV/36kV.
Screened cable T-plugs, also known as separable connectors, are specified to terminate and connect 33kV power cables into Siemens NXPLUS C gas insulated switchgear – the external semi-conductive layer must be earthed normally via a cable connector.
Insulated cable T-plugs (without semi-conductive layer) are not permissible – this type of MV cable plug or connector is prone to partial discharge due to the proximity to earthed parts of the switchgear. Partial discharge destroys the MV cable connector causing an arc between phase and earth.
The connection of conventional 33kV cable sealing ends or terminations via elbow adapters is not permissible either as this type of medium voltage power system is also insulated but not screened (no external semi-conductive layer).

| Circuit-breaker Panels 630 A / 800 A 33kV/36kV |
| Number Of Cables Per Panel & Phase |
Connector Manufacturer |
Rated voltage |
Conductor Cross- Section sqmm |
Cable Insulation |
T-Plugs/Phase Bolted |
Coupling Inserts/ Coupling Plugs / Bolted |
Surge Arresters With Coupling Arresters/Phase |
Inserts Coupling Unit |
| 1 |
Nexans Euromold |
36kV |
50 to 240 |
EPDM |
1x M400TB/G |
– |
1x 400PB-5(10)SA-xxx |
– |
| 36kV |
50 to 240 |
EPDM |
1x M430TB/G |
– |
1x 300SA-10-xx |
– |
| 36kV |
50 to 630 |
EPDM |
1x M484TB/G |
– |
1x 800SA-10-xx |
– |
| 36kV |
300 to 630 |
EPDM |
1x M440TB/G |
– |
1x 400PB-5(10)SA-xxx |
– |
| Südkabel |
36kV |
70 to 300 |
Silicone |
1x SET 36 |
– |
– |
– |
| 36kV |
70 to 500 |
Silicone |
1x SEHT 33 |
– |
1x MUT 33 |
1x KU 33 |
| nkt Cables |
36kV |
25 to 300 |
Silicone |
1x CB 36-630 |
– |
1x CSA36-10 |
– |
| 36kV |
400 to 630 |
Silicone |
1x CB 36-630(1250) |
– |
1x CSA36-10 |
– |
| Tyco Electronics Raychem |
36kV |
25 to 300 |
Silicone |
1x RSTI-66xx |
– |
1x RSTI-CC-66SAxxx |
– |
| 36kV |
25 to 300 |
Silicone |
1x RSTI-68xx |
– |
– |
– |
| 36kV |
400 to 630 |
Silicone |
1x RSTI-66Lxx |
– |
1x RSTI-66SAxxx |
1x RSTI66CP-M16 |
| 36kV |
400 to 800 |
Silicone |
1x RSTI-69xx |
– |
– |
– |
| 2 |
Nexans Euromold |
36kV |
50 to 240 |
EPDM |
2x M400TB/G |
1x M400CP |
– |
– |
| 36kV |
50 to 240 |
EPDM |
1x M430TB/G |
1x M300PBM-630A |
1x 300SA-10-xx |
– |
| 36kV |
50 to 360 |
EPDM |
1x M484TB/G |
1x M804PB/G |
– |
– |
| 36kV |
300 to 630 |
EPDM |
2x M440TB/G |
1x M400CP |
– |
– |
| Südkabel |
36kV |
70 to 500 |
Silicone |
2x SEHT 33 |
1x KU 33 |
– |
– |
| nkt cables |
36kV |
25 to 300 |
Silicone |
1x CB 36-630 |
1x CC36-630 |
1x CSA36-10 |
– |
| 36kV |
25 to 300 |
Silicone |
2x CB 36-630 |
1x CP 630C |
– |
– |
| 36kV |
400 to 630 |
Silicone |
2x CB 36-630(1250) |
1x CC36-630(1250) |
1x CSA36-10 |
– |
| 36kV |
400 to 630 |
Silicone |
2x CB 36-630(1250) |
1x CP 630C |
– |
– |
| Tyco Electronics Raychem |
36kV |
25 to 300 |
Silicone |
1x RSTI-66xx |
1x RSTI-CC-66xx |
– |
– |
| 36kV |
25 to 300 |
Silicone |
1x RSTI-68xx |
1x RSTI-CC-68xx |
– |
– |
| 36kV |
400 to 630 |
Silicone |
2x RSTI-66Lxx |
1x RSTI-66CP-M16 |
– |
– |
| 36kV |
400 to 800 |
Silicone |
1x RSTI-69xx |
1x RSTI-CC-69xx |
– |
– |
1) Observe the actual short-circuit and current carrying capacity of the cables and sealing ends
| Disconnector Panel 630 A / 800 A, ring-main panel 630 A 33kV/36kV |
| Number Of Cables Per Panel & Phase |
Connector Manufacturer |
Rated Voltage |
Conductor Cross- Section sqmm |
Cable Insulation |
T-Plugs / Phase / Bolted |
Coupling Inserts/ Coupling Plugs / Bolted |
Surge Arresters With Coupling Arresters / Phase |
Inserts Coupling Unit |
| 1 |
Nexans Euromold |
36kV |
50 to 240 |
EPDM |
1x M400TB/G |
– |
1x 400PB 5(10) SA-xxx |
– |
| 36kV |
50 to 240 |
EPDM |
1x M430TB/G |
– |
1x 300SA-10-xx |
– |
| 36kV |
50 to 630 |
EPDM |
1x M484TB/G |
– |
1x 800SA-10-xx |
– |
| 36kV |
300 to 630 |
EPDM |
1x M440TB/G |
– |
1x 400PB 5(10) SA-xxx |
– |
| Südkabel |
36kV |
70 to 500 |
Silicone |
1x SET 36 |
– |
– |
– |
| 36kV |
70 to 500 |
Silicone |
1x SEHT 33 |
– |
1x MUT33 |
1x KU33 |
| nkt Cables |
36kV |
25 to 300 |
Silicone |
1x CB36-630 |
– |
1x CSA36-10 |
– |
| 36kV |
400 to 630 |
Silicone |
1x CB36-630(1250) |
– |
1x CSA36-10 |
– |
| Tyco Electronics Raychem |
36kV |
25 to 300 |
Silicone |
1x RSTI-66xx |
– |
1x RSTI-CC-66SAxxx |
– |
| 36kV |
25 to 300 |
Silicone |
1x RSTI-68xx |
– |
– |
– |
| 36kV |
400 to 630 |
Silicone |
1x RSTI-66Lxx |
– |
1x RSTI-CC-66SAxxx |
1x RSTI-66CPM16 |
| 36kV |
400 to 800 |
Silicone |
1x RSTI-69xx |
– |
– |
– |
| 2 |
Nexans Euromold |
36kV |
50 to 240 |
EPDM |
2x M400TB/G |
1x M400CP |
– |
– |
| 36kV |
50 to 240 |
EPDM |
1x M430TB/G |
1x M300PB/G |
– |
– |
| 36kV |
50 to 630 |
EPDM |
1x M484TBG |
1x M804PB/G |
1x 800SA-10-xx |
– |
| 36kV |
300 to 630 |
EPDM |
2x M440TB/G |
1x M400CP |
– |
– |
| Südkabel |
36kV |
70 to 500 |
Silicone |
2x SEHT 33 |
1x KU33 |
– |
– |
| nkt Cables |
36kV |
25 to 300 |
Silicone |
1x CB36-630 |
1x CC36-630 |
1x CSA36-10 |
– |
| 36kV |
25 to 300 |
Silicone |
2x CB36-630 |
1x CP-630C |
1x CSA36-10 |
– |
| 36kV |
400 to 630 |
Silicone |
1x CB36-630(1250) |
1x CC36-630(1250) |
1x CSA36-10 |
– |
| 36kV |
400 to 630 |
Silicone |
2x CB36-630(1250) |
1x CP-630C |
– |
– |
| Tyco Electronics Raychem |
36kV |
25 to 300 |
Silicone |
1x RSTI-66xx |
1x RSTI-CC-66xx |
1x RSTI-CC-66SAxxx |
– |
| 36kV |
25 to 300 |
Silicone |
1x RSTI-68xx |
1x RSTI-CC-68xx |
– |
– |
| 36kV |
400 to 630 |
Silicone |
2x RSTI-66Lxx |
1x RSTI-66CP-M16 |
1x RSTI-CC-66SAxxx |
1x RSTI-66CPM16 |
| 36kV |
400 to 800 |
Silicone |
1x RSTI-69xx |
1x RSTI-CC-69xx |
– |
– |
| 3 |
Nexans Euromold |
36kV |
50 to 240 |
EPDM |
1x M430TB/G |
1x M300PBM- 630A |
– |
– |
| nkt Cables |
36kV |
25 to 300 |
Silicone |
1x CB36-630 |
2x CC36-630 |
– |
– |
| 36kV |
2x CP-630C |
– |
– |
| 36kV |
400 to 630 |
Silicone |
1x CB 36-630(1250) |
2x CC36-630(1250) |
– |
– |
| 36kV |
400 to 630 |
Silicone |
2x CB 36-630(1250) |
1x CP-630C |
– |
– |
| Tyco Electronics Raychem |
36kV |
25 to 300 |
Silicone |
1x RSTI-66xx |
2x RSTI-CC-66xx |
– |
– |
| 36kV |
25 to 300 |
Silicone |
1x RSTI-68xx |
2x RSTI-CC-68xx |
– |
– |
| 36kV |
400 to 630 |
Silicone |
3x RSTI-66Lxx |
2x RSTI-66CP-M16 |
– |
– |
| 36kV |
400 to 800 |
Silicone |
1x RSTI-69xx |
2x RSTI-CC-69xx |
– |
– |
1) Observe the actual short-circuit and current carrying capacity of the cables and sealing ends
33kV Cables
Cable T-Plug Connectors
The following table outlines the screened separable connector, also referred to as cable sealing ends, suitable for 33kV/36kV cables according to IEC 60502-2 and VDE 0276-620.
The cable T-plug connection types are suitable for medium voltage bushings with outside cone as Interface C Type Bushings according to EN50181 for 33kV cables with conductor cross-section up to 800sqmm copper/aluminium.
| Cable Type 33kV/36kV |
Connector Manufacturer |
33kV Cable Connector Type |
Cross-Section sqmm |
Comment |
| 1-core cable, PE and XLPE- insulatedN2YSY (Cu) and N2XSY (Cu) orNA2YSY (Al) and NA2XSY (Al) |
Nexans Euromold |
M400TB/G |
50 to 240 |
EPDM with semi-conductive layer |
| M430TB/G |
50 to 240 |
EPDM with semi-conductive layer |
| M484TB/G |
70 to 630 |
EPDM with semi-conductive layer |
| M440 TB/G |
300 to 630 |
EPDM with semi-conductive layer |
| nkt cables |
CB 36-630 |
25 to 300 |
Silicone with semi-conductive layer (optionally with metal housing) |
| CB 36-630(1250) |
400 to 630 |
Silicone with semi-conductive layer (optionally with metal housing) |
| Südkabel |
SEHDT 33 |
70 to 500 |
Silicone with semi-conductive layer (optionally with metal housing) |
| Tyco Electronics Raychem |
RSTI-66xx |
25 to 240 |
Silicone with semi-conductive layer, with capacitive measuring point |
| RSTI-68xx |
25 to 240 |
Silicone with semi-conductive layer, with capacitive measuring point |
| RSTI-66Lxx |
400 to 630 |
Silicone with semi-conductive layer, with capacitive measuring point |
| RSTI-69xx |
400 to 800 |
Silicone with semi-conductive layer, with capacitive measuring point |

N2XSY XLPE PVC – 18/30 (36)kV Cable Connectors
33kV Surge Arresters
Surge arresters for pluggable onto cable T-plugs and are recommened for MV-HV cable and power systems:
- if the 33kV cable is directly connected to the overhead line
- if the protection zone of the 33kV surge arrester at the end tower of the overhead line does not cover the high voltage switchgear
- in offshore wind farms
| Surge Arrester 33kV/36kV |
1 Cable Per Phase |
2 Cables Per Phase |
| Circuit-breaker Panel |
Disconnector Panel |
Ring-main Panel |
Circuit-breaker Panel |
Disconnector Panel |
Ring-main Panel |
| Nexans Euromold 400PB-10-SA-45L |
X |
X |
X |
– |
– |
– |
| Nexans Euromold 300SA-10-xx |
X |
X |
X |
X |
X |
X |
| Südkabel MUT 33 + KU 33 |
– * |
X |
X |
– |
– |
– |
| nkt Cables CSA 36-10 |
X |
X |
X |
X** |
X |
X |
| Tyco Electronics Raychem RSTI-CC-66SAxxx |
–* |
X |
X |
–* |
X |
X |
| Tyco Electronics Raychem RSTI-66SAxxx |
–* |
X |
X |
–* |
X |
X |
* protrudes into the floor area; possible depending on the local conditions, e.g. with sufficient hole depth
** depending on the cable plug type – contact T&D to discuss possible combinations of cable connection types and surge arresters in NXPLUS C Wind up to 36kV.
➡ View complete range of Surge Arresters 11kV 33kV MV HV
Screened separable connectors and surge arresters must be provided by the same manufacturer and used only with one cable connected per 33kV phase. Some types of surge arresters exceed the permissible dimensions as outlined in the table above.

Credit ABB – Joint, Terminate & Connect Medium & High Voltage Cables
Thorne & Derrick
T&D are UK distributors and worldwide exporters of Cable Installation, Cable Jointing, Duct Seals, Substation & High Voltage Electrical Safety Equipment – we service UK and global businesses involved in cable installations, jointing, substation, overhead line and electrical construction at LV, 11kV, 33kV and EHV.
Since 1985, T&D have established a solid reputation based on Service, Integrity and Trust – contact us with your enquiry.